Shear Wave Ultrasound Liver Assessment
klas award masthead with logo

Shear wave elastography Simplify liver disease assessment

The value of elastography

 

Philips shear wave elastography simplifies liver assessment, making obtaining liver stiffness measurements fast and easy. This non-invasive, reproducible, and easily performed method of assessing  liver tissue stiffness may help reduce, or even avoid, the need for conventional liver biopsies1. Research suggests that instead of a costly and painful biopsy procedure, an easy ultrasound exam could become routine for assessing liver disease status.

*

Contact information

* This field is mandatory

*
*
*
*
*
*
*
*
*

By specifying your reason for contact we will be able to provide you with a better service.

We work with partners and distributors who may contact you about this Philips product on our behalf.

*
*

Final CEE consent

Elastography in liver assessment:

ElastPQ (P-SWE) has proven valuable in staging liver disease, reducing the need for costly and potentially painful biopsies in some patients. ElastQ (2D-SWE) advances shear wave elastography, providing a technique that is not only noninvasive and easy to use, but also offers clinicians additional confidence in the reliability of measurements, even for the technically difficult patient (TDP), such as a patient with a high BMI. 

shear elastq

ElastQ imaging

ElastQ imaging is a real-time, large Region of Interest (ROI), color-coded quantitative assessment of tissue stiffness. It is the only solution to offer both PureWave technology and high frame rate real-time shear wave imaging across abdominal applications. Clinicians can easily assess liver tissue stiffness using real-time feedback and make quantitative measurements with multiple sample points even retrospectively on DICOM stored images. Unique confidence map, used with the stiffness map, improve confidence of shear wave measurements. Both maps can be displayed side-by-side, which reduces workflow steps and allows for simultaneous map correlation during acquisition and measurement phases.

ultrasound c5-1 transducer liver abdominal ultrasound

ElastPQ

ElastPQ is an easy-to-use method of obtaining tissue stiffness values of the liver on a predefined ROI. Using real-time imaging as a guide, the ROI is placed over the area of interest and tissue stiffness data such as AVG, MEAN, and IQR are obtained and displayed in seconds. Multiple samples can be recorded and liver tissue report generated from the results.

non invasive liver fibrosis

Noninvasive liver fibrosis assessment

ElastPQ ultrasound shear wave elastography

 

Richard G. Barr, MD, PhD, FACR, Diagnostic Radiology,
Hitchcock Imaging, Youngstown, OH


Download now

 

eorie image

Introducing next-generation shear wave elastography

ElastQ ultrasound shear wave elastography

 

Vijay Shamdasani, PhD and Hua Xie, PhD, Philips Ultrasound 

 

Download now

Noninvasive liver assessment made easy

 

The liver stiffness measurement is captured in seconds through a simple noninvasive scan

liver assessment

Easily assess and monitor patients

Shear Wave Map

Chronic Hepatitis C worldwide

 

  • 130-150 million people affected
  • 4.7 million new cases annually
  • 350,000-500,000 deaths annually
  • 130-150 million people affected
  • 4.7 million new cases annually
  • 350,000-500,000 deaths annually
  • Shear wave elastography is supported on the EPIQ EliteEPIQ 7EPIQ 5, and Affiniti 70 ultrasound systems.

    1 Ferraioli G, et al. Point shear wave elastography method for assessing liver stiffness. World J Gastroenterology. 2014 April 28;20(16):4787-4796.